Automation And Power Solutions Est. (A&P Solutions), is a Multinational Company with diversified and multi-disciplinary Contracting, Trading and Training activities ranging.
XMI-D series UPS is specifically designed for electrical power systems, significantly enhancing the reliability of the power supply system. It completely eliminates the impact, surges, sags, and noise interference of the power grid. With outstanding quality, excellent performance, and user-friendly operation, it provides green and reliable power protection for loads.
ABOUT HQ-MR ONLINE RACKMOUNT MODULAR UPS
Supports hot standby for parallel machines, N+X redundant parallel operation, providing highly reliable power.
Optional monitoring protocols compatible with backend power device monitoring, featuring user-friendly monitoring functions.
Humanized control design with no strict operating sequence, ensuring simple and safe usage.
Stable and reliable power supply.
SPECIFICATION
| Model | XMI10D(R/P) | XMI20D(R/P) | XMI30D(R/P) | XMI50D(R/P) | XMI75D(R/P) | XMI80D(R/P) | XMI1110D(R/P) |
| Capacity | 1kVA | 2kVA | 3kVA | 5kVA | 7.5kVA | 8kVA | 10kVA |
| Input | |||||||
| Rated Voltage | 220Vac | ||||||
| Voltage Range | Phase voltage (165 ~ 275) Vac | ||||||
| Frequency Range | (50 ± 5%)Hz | ||||||
| Rated DC Voltage | 110/220Vdc | ||||||
| Output | |||||||
| Rated Voltage | Single phase 220Vac | ||||||
| Voltage Accuracy | (220 ± 1%)Vac | ||||||
| Output Frequency | (50 ± 0.5%)Hz | ||||||
| Power Factor | 0.8 | ||||||
| THDu | <3% (linear full load), <5% (non-linear full load) | ||||||
| Overload Capacity | 105%~125%, switch to bypass in 10 min; 125%~150%, switch to bypass in 1 min; >150%, immediately switch to bypass | ||||||
| Switching Time | 0ms | ||||||
| Current imbalance in parallel operation | ≤5% | ||||||
| Protection | |||||||
| Overload | Switch to bypass power supply, automatically switch to mains power after load reduction | ||||||
| Overheat | >85℃, switch to bypass power supply | ||||||
| Short Circuit | Inverter shutdown with protection alarm | ||||||
| Fault | Switch to bypass with protection alarm | ||||||
| Undervoltage | Automatic shutdown | ||||||
| Display | |||||||
| LED Indication | AC power indicator, inverter indicator, bypass indicator, DC undervoltage indicator, overload indicator, fault indicator | ||||||
| LCD Display | AC input/output voltage, AC input/output frequency, DC input voltage, load precentage, apparent power, active power, output current, UPS operating status | ||||||
| Other Function | |||||||
| Alarm | Input abnormality, low battery voltage, overload, and other error | ||||||
| Communication | Standard RS-232/RS485 (supporting Modbus protocol), dry contact; SNMP remote monitoring (optional) | ||||||
| Environment | |||||||
| Operating Temperature | (-5 ~ 40)℃ | ||||||
| Relative Humidity | 0~95% (no condensation) | ||||||
| Noise | <55dB @ 1 meter | ||||||
| Mechanical Indicators | |||||||
| Rack-mount with internal transformer width x depth x height (mm) | 422 x 461 x 176(4U) | 422 x 419 x 352(8U) | 442 x 419 x 442(10U) | 440 x 470 x 712(16U) | |||
| Rack-mount with external transformer width x depth x height (mm) | 482 x 440x 264(6U) | 482 x 440 x 264(6U DC220V) 440 x 440 x 311(7U DC110V) | |||||
| Rack-mount weight | 46 (internal) | 46 (internal) | 46 (internal) | 85 (internal) 22 (external) | 100 (internal) 28/30 (external) | 142 (internal) 28/30 (external) | 145 (internal) 28/30 (external) |